• Info
  • Downloads

Pumping stations with 1 and 2 pumps light polluted water

Available in a tank of 850 liters.

Equipped with a Pedrollo pump RMx 2/20, RMx 5/40, MCm 10/45 or MCm 15/45.

Suitable for rainwater with small pollution, such as mud in emptying building sellers, water after water treatment plant, …

Specifications

Pumping stations with 1 pump:

The water that has to be transported to a higher level enters a tank of 850 litres via the inlet. In that tank are 1 pump and 3 floating switches installed.

From the moment there is enough water in the tank, the middle floating switch starts the pump. From the moment on that the minimum level is reached, the lower floating switch will turn the pump of.

When the upper floating switch detects liquid, the alarm goes on.

Pumping stations with 2 pumps:

The water that has to be transported to a higher level enters a tank of 850 litres via the inlet. In that tank are 2 pumps and 3 floating switches installed.

From the moment there is enough water in the tank, the middle floating switch starts pump number 1. From the moment on that the minimum level is reached, the lower floating switch will turn of pump 1.

The next time water is coming in the tank, pump number 2 will work. The 2 pumps work alternately.

When the upper floating switch detects liquid, the alarm goes on.

These installations are equipped with a control box with alarm, where the connexion with the pump(s) and the floating switches must be realized.

The pumps stand on the bottom of the tank and are of the type Pedrollo TRITUS TRm.

INCLUDED: One-way valve

Download our technical sheet to learn more about the pump, the flow rates and the maximum head. 

Designs:
Available in a tank of 850 litres
Equipped with a Pedrollo pump TRITUS TRm.
Equipped with a sieve basket at the inlet.
An outlet in PVC pressure  50/63. As an option, a connection is available from the  PVC outlet to reinforced PE tube with an external diameter of 50 or 63 mm.
Suitable for sewage water with larger particles, such as faecal water from houses or rafter a septic tank, …

Table

Description
Diameter
Height
Diameter in
Diameter out
Height in
Hoogte out
Manhole
Kg
PP850/1/RXm 2/20
930
1.680
110
50/63
1.100
1.350
600
57
PP850/2/RXm 2/20
930
1.680
110
50/63
1.100
1.350
600
64
PP850/1/RXm 5/40
930
1.680
110
50/63
1.100
1.350
600
65
PP850/2/RXm 5/40
930
1.680
110
50/63
1.100
1.350
600
80
PP850/1/MCm 10/45
930
1.680
110
50/63
1.100
1.350
600
70
PP850/2/MCm 10/45
930
1.680
110
50/63
1.100
1.350
600
90
PP850/1/MCm 15/45
930
1.680
110
50/63
1.100
1.350
600
71
PP850/2/MCm 15/45
930
1.680
110
50/63
1.100
1.350
600
92